Skip to main content
Tai Sin LT Line I Busbar Trunking System (a.k.a Busway, Bus Duct) is a reliable and efficient electrical distribution system with sandwich construction and superior performance. It is a safe and robust power distribution system with high electrical efficiency, low voltage drop, high mechanical strength.

Busbar Trunking System Designed & Tested in Singapore

Tai Sin LT Line I Busbar Trunking System (a.k.a Busway, Bus Duct) is a reliable and efficient electrical distribution system with sandwich construction and superior performance. It is a safe and robust power distribution system with high electrical efficiency, low voltage drop, and high mechanical strength.

Our system offers a full line of busbar trunking systems to meet most requirements. Offering 3P3W, 3P4W, 3P5W, supply and distribution, with rated current from 250A to 4000A (for aluminum conductor) & 400A to 5000A (for copper conductor), rated operation and insulation voltage up to 1000V, IP degree up to IP66 and the frequency 50~60Hz.

VIEW CATALOGUE

Features

With Tai Sin Busbar Trunking System, you can always find the optimal solution to meet the challenges ahead. Scroll to look at the features of our LT Line I Busbar Trunking System.

With Tai Sin Busbar Trunking System, you can always find the optimal solution to meet the challenges ahead.
Unique Structure Design Unique “serrated surface” design of extruded aluminum housing greatly improves the heat dissipation for the whole busway system.

Unique Structure Design

Unique “serrated surface” design of extruded aluminium housing greatly improves the heat dissipation for the whole busway system.

Novel Conductor Structure State-of-the-art welding processes with compact arrangement to create a true sandwich structure.

Novel Conductor Structure

State-of-the-art welding processes with a compact arrangement to create a true sandwich structure.

Robust Sandwich Structure Densely arranged conductors in the housing to achieve superior heat dissipation, lower temperature rise and eliminate the “chimney effect”.

Robust Sandwich Structure

Densely arranged conductors in the housing to achieve superior heat dissipation, lower temperature rise and eliminate the “chimney effect”.

Superior & Reliable Insulation Both polyester film insulation and epoxy insulation (Class B) are available with exceptional electrical performance and superior mechanical strength. Environmental friendly materials are applied with certification by reputed international laboratory. The busway system is halogen-free with no toxicity emission in case of fire.

Superior & Reliable Insulation

Both polyester film insulation and epoxy insulation (Class B) are available with exceptional electrical performance and superior mechanical strength. Environmental-friendly materials are applied with certification by a reputed international laboratory. The busway system is halogen-free with no toxicity emission in case of fire.

Compact Design The dimension of LV busway begins at 125mmx103mm for 400-630A ratings with very compact design. Bus plug is also compressive and dimension begins at 360mm×250mm×255 mm for 100A, giving more space for other equipments.

Compact Design

The dimension of the LV busway begins at 125mmx103mm for 400-630A ratings with a very compact design. The bus plug is also compressive and dimension begins at 360mm×250mm×255 mm for 100A, giving more space for other equipment.

 

99.9% Purity Copper Conductor High-speed sawing for a high sawing accuracy and smooth cut to reduce temperature rise at the busway joint.

99.9% Purity Copper Conductor

High-speed sawing for high sawing accuracy and smooth cut to reduce temperature rise at the busway joint.

 

Unique Error-proof Device A bridge type joint is devised to prevent potential damage on busbar due to incorrect connection.

Unique Error-proof Device

A bridge-type joint is devised to prevent potential damage on the busbar due to incorrect connection.

Unique Joint Design Single bolt joint design to shorten the time of connection by 50% compared to the traditional design. Double headed “break off” joint bolt to tighten the busway with just a common 16mm socket wrench. Belleville spring washers are adopted to ensure pressure evenly applied across the joint.

Unique Joint Design

Single bolt joint design to shorten the time of connection by 50% compared to the traditional design.
Double-headed “break off” joint bolt to tighten the busway with just a common 16mm socket wrench. Belleville spring washers are adopted to ensure the pressure is evenly applied across the joint.

Predictive Temperature Rise Indicator Joint insulator with a convex-concave groove edge provides an increased creepage distance. Color-coded-temperature indicator applied at busway joint is to give an early warning when high temperature occurs at the joint.

Predictive Temperature Rise Indicator

  • Joint insulator with a convex-concave groove edge provides an increased creepage
    distance.
  • Color-coded-temperature indicator applied at the busway joint is to give an early warning when high temperature occurs at the joint.
Safe Plug outlet and Busbar plug Both outlet phase tabe and plug stab fingers are fully silver-plated The bus plug has complete safty interlock mechanism to ensure electric safty The plug outlet protection module is embedded with waterproof silicone rubber, up to IP54 Up to 10 plug outlets can be installed every 3 m of straight length busway

Safe Plug outlet and Busbar plug

  • Both outlet phase tabe and plug stab fingers are fully silver-plated
  • The bus plug has a complete safety interlock mechanism to ensure electric safety
  • The plug outlet protection module is embedded with waterproof silicone rubber, up to IP54
  • Up to 10 plug outlets can be installed every 3 m of straight-length busway
With Tai Sin Busbar Trunking System, you can always find the optimal solution to meet the busbar challenges ahead.

Our Certifications

  • Product and production location will be under surveillance of KEMA
  • Ensure product produced identical to those originally tested
  • Complete IEC61439-6 type tests
  • The certification mark can be applied to the label as per specified duration of the certification
  • Certification Validity will be published on KEMA website
  • Resistance to flame progagation
  • Fire resistance in building penetration
  • Resistance of insulating materials to abnormal heat & fire